Positek X005 galvanic isolation amplifier

Image: Positek

Positek · X005

X005 ATEX Approved Galvanic Isolation Amplifier

ATEX / IECEx / UKEX approved amplifier for Positek intrinsically safe sensors; 2.5 kV isolation, 4.7 kHz bandwidth.

Request a quote

The X005 is a galvanic isolation amplifier designed for Positek intrinsically safe position sensors; it can also be used with suitable potentiometer based sensors. It provides tri-port isolation between the supply, the hazardous area and the output. It operates in three or five wire mode and compensates up to 15 Ω conductor resistance. The output is factory configured to 0.5–9.5 V or 4–20 mA.

Technical specifications
Intrinsic safetyEx II (1)GD [Ex ia Ga] IIC, [Ex ia Da] IIIC; Ex I (M1) [Ex ia Ma] I (-20 °C ≤ Ta ≤ +60 °C)
ApprovalsATEX, IECEx, UKEX
Supply voltage24 V DC nominal (12–30 V)
Output options0,5–9,5 V; 9,5–0,5 V; 4–20 mA; 20–4 mA
BandwidthDC – 4,7 kHz (-3 dB)
Non-linearity< ±0,1 % FS
Isolation2500 V (güvenli alan – tehlikeli alan klemensleri)
Sensor supply5 V, maks. 15 mA
Operating temperature-20 °C ile +60 °C
Protection classIP20
Mounting35 x 7,5 mm IEC/EN 60715 DIN (top-hat) ray
Dimensions97,3 x 22,5 x 111,9 mm

Applications

  • Intrinsically safe sensor circuits
  • Hazardous to safe area signal isolation
  • Servo control loops

Datasheet (manufacturer page) ↗Manufacturer / supplier page ↗

Other products in this group

Product images belong to their respective manufacturers. Prices and stock are not shown; availability is confirmed at quotation.