CIRCUIT BREAKER
| NSN | 5925-00-089-3031 |
|---|---|
| NIIN | 000893031 |
| Class (FSC) | 5925 · CIRCUIT BREAKERS |
| Group (FSG) | 59 · Electrical And Electronic Equipment Components |
| Unit of issue | EA |
| DMIL | A |
Item definition
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES:CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.
Technical characteristics
| BUSHING LENGTH | INCHES NOMINAL 0.375 |
|---|---|
| BODY LENGTH | INCHES NOMINAL 1.375 |
| BODY WIDTH | INCHES NOMINAL 0.687 |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | INCHES NOMINAL 1.020 |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| MOUNTING SURFACE TO TERMINAL END DISTANCE | INCHES NOMINAL 2.035 |
| POLE QUANTITY | 1 |
| ARC QUENCHING METHOD | AIR |
| MOUNTING FACILITY TYPE AND QUANTITY | THREADED BUSHING 1 |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| THREAD QUANTITY PER INCH | 24 |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | SINGLE LOCATION AMPERES AC 7.5 AND AMPERES DC 7.5 |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | SINGLE LOCATION AC 250.0 AND DC 50.0 |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | SINGLE LOCATION AC 1000.0 AND DC 2500.0 |
| CIRCUIT PROTECTION TYPE | SINGLE LOCATION OVERCURRENT |
| TRIP RELEASE METHOD | SINGLE LOCATION THERMAL |
| TRIP RELEASE CHARACTERISTIC | SINGLE LOCATION TIME DELAY |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 135.0 |
| RESET METHOD | MANUAL |
| MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| MANUAL ACTUATOR TYPE AND QUANTITY | PUSH-PULL 1 |
| ACTUATOR FUNCTION | TRIP-RESET |
| ACTUATOR POSITION DESIGNATION | AT POLE ONE |
| INTERNAL TRIP RELEASE CONFIGURATION | SINGLE LOCATION SERIES TRIP |
| NOMINAL THREAD SIZE | INCHES 0.375 |
| TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | SINGLE LOCATION MINIMUM AT 200 PCT 6.000 AND MAXIMUM AT 200 PCT 20.000 |
| INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | HUMIDITY RESISTANT AND SALT SPRAY PROOF AND SHOCK RESISTANT AND VIBRATION RESISTANT |
| TRIP RELEASE AMBIENT TEMP RATING | SINGLE LOCATION CELSIUS MAXIMUM 25.0 |
| UNPACKAGED UNIT WEIGHT | OUNCES NOMINAL 2.000 |
| FREQUENCY IN HERTZ | 400.0 |
| MATERIAL | CASE PLASTIC |
| THREAD SERIES DESIGNATOR | UNF |
| TERMINAL TYPE AND QUANTITY | SCREW 2 |