NSN 5915-00-134-0291
Request a quoteFILTER, BAND PASS
| NSN | 5915-00-134-0291 |
|---|---|
| NIIN | 001340291 |
| Class (FSC) | 5915 · FILTERS AND NETWORKS |
| Group (FSG) | 59 · Electrical And Electronic Equipment Components |
| Unit of issue | EA |
| DMIL | D |
This item may be subject to export control; an end-user statement is required.
Item definition
AN ITEM DESIGNED TO PASS FREQUENCIES WITHIN A SPECIFIED RANGE (BAND) AND TO SUPPRESS FREQUENCIES OUTSIDE THE RANGE (BAND). EXCLUDES:A SINGLE INDUCTANCE, OR A SINGLE CAPACITANCE, OR A SINGLE RESISTANCE. SEE COIL (AS MODIFIED); REACTOR; CAPACITOR (AS MODIFIED); AND RESISTOR (AS MODIFIED).
Technical characteristics
| OVERALL LENGTH | INCHES NOMINAL 12.000 |
|---|---|
| BODY OUTSIDE DIAMETER | INCHES NOMINAL 0.500 |
| VIBRATION RESISTANCE RANGE IN HERTZ | 5.0 TO 55.0 |
| REFERENCE FREQUENCY PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED MEGAHERTZ BLANK 125.0 |
| SOURCE IMPEDANCE RATING PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED OHMS BLANK 50.0 |
| LOAD IMPEDANCE PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED OHMS BLANK 50.0 |
| INPUT TERMINAL MANUFACTURER CODE | 30003 |
| INPUT TERMINAL IDENTIFICATION | SMA-RECEPTACLE |
| OUTPUT TERMINAL MANUFACTURER CODE | 30003 |
| OUTPUT TERMINAL IDENTIFICATION | SMA-RECEPTACLE |
| VOLTAGE STANDING WAVE RATIO PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED BLANK 1.5 |
| AVERAGE POWER RATING PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED WATTS BLANK 2.0 |
| INCLOSURE TYPE | ENCASED |
| MOUNTING FACILITY TYPE AND QUANTITY | LOCATION NOT OTHERWISE SPECIFIED TERMINAL 2 |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | LOCATION NOT OTHERWISE SPECIFIED BLANK 1.5 |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | FIRST FUNCTION CONNECTOR, RECEPTACLE INPUT 1 |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | SECOND FUNCTION CONNECTOR, RECEPTACLE OUTPUT 1 |
| SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED MEGAHERTZ BLANK 62.00 AND MEGAHERTZ BLANK 90.00 AND MEGAHERTZ BLANK 160.00 AND MEGAHERTZ BLANK 186.00 |
| FREQUENCY BAND WIDTH PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED MEGAHERTZ BLANK 90.00 AND MEGAHERTZ BLANK 160.00 |
| DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | FIRST FUNCTION MINIMUM BLANK 60.0 AND MAXIMUM BLANK 3.0 |
| VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED MEGAHERTZ BLANK 90.0 AND MEGAHERTZ BLANK 160.0 |
Source: US Defense Logistics Agency (DLA) FLIS open data. For information only; price and stock are not stated, availability is confirmed at quotation.